新しい昇降法の推定量の偏りについて
Bias in the Estimation of the New Up-and-Down
Method
|
|
|
|
|
|
|
|
小守, 廣瀬
Y. Komori, H. Hirose
|
|
|
|
|
|
|
|
Information, Vol.3, No.2,
pp.183-192 (2000.4)
|
|
|
|
|
|
The flashover voltage estimation has been carried
out with the up-and-down method by Dixon et al. (1948) conventionally.
On the other hand, Hirose et al. (Hirose:1998,Hirose:1999) proposed
a new version of the method to change the way of analyzing data,
and asserted that their new method had an advantage to give better
confidence interval for the estimate.
In this paper we are concerned with an issue on the bias in the
estimator of the new method and investigate it analytically. This
makes it clear the relationship between the new and the conventional
ones. All the results are numerically confirmed.
|
|
|
|
|
flashover voltage, estimation, up-and-down
method, bias
|
|
|
|
|
|
|
|
|
Times Cited in Web of Science:
Cited in Books:
|
|
|
|
|
|
|
|